Home>Products>TEMPERATURE CONTROL

TEMPERATURE CONTROL

Laboratory Temperature Control Equipment & Circulating Baths

Laboratory temperature control equipment including refrigerated circulating baths, -80°C ultra-low-temperature baths, calibration baths, and process circulators.

Lithostek laboratory temperature control equipment is organized around the parameters that determine real application fit: working temperature range, cooling capacity at the required setpoint, temperature stability and uniformity, usable bath dimensions, circulation mode, pump performance, heat-transfer fluid compatibility, and site power. The range covers refrigerated circulating baths, metrology calibration baths, dynamic heating and cooling circulators, immersion coolers, and application-specific viscometer baths.

Performance Selection Criteria

Start with the required setpoint

Specify the lowest and highest operating temperatures, ambient conditions, target fluid, and whether the bath must hold temperature under an active heat load.

Compare cooling capacity at temperature

A minimum temperature alone does not define performance. Request cooling capacity at 20°C, 0°C, and the actual low-temperature operating points used by the process.

Confirm bath geometry and circulation

Check usable opening, depth, fluid volume, internal or external circulation, pump flow, pressure, and connection size against the intended vessel or specimen.

Verify fluid and electrical configuration

Select a heat-transfer fluid compatible with the full operating range and confirm voltage, frequency, total input power, ventilation clearance, and safety options.

Laboratory Temperature Control Equipment Laboratory Setup

Plan a complete Laboratory Temperature Control Equipment laboratory around your daily methods. Lithostek integrates equipment configuration, performance verification, calibration documentation, operator training, and service support for application-specific research, quality-control, and process workflows.

Consult Engineering

Frequently Asked Questions

A refrigerated circulating bath actively heats, cools, and circulates a temperature-control fluid. Water is suitable only for a limited temperature range; ultra-low-temperature operation requires a compatible heat-transfer fluid selected for the target setpoint and equipment materials.

Confirm the working temperature range, cooling capacity at the actual setpoint, temperature stability and uniformity, usable opening and depth, fluid volume, pump flow and pressure, heat-transfer fluid, ambient conditions, and electrical supply.

Yes. The application review covers the external vessel or heat exchanger, hose length, connection size, elevation, pressure drop, heat load, target ramp rate, fluid compatibility, and required safety interlocks before quotation.

Need More Information?

Contact our team to learn more about our laboratory temperature control equipment solutions and find the perfect equipment for your needs.

Get A Quote
RETURN TO TOP ↑