LS-CB180 Wide-Range Temperature Calibration Bath

Configured by setpoint, heat load, fluid, and circulation requirements

LS-CB180 Wide-Range Temperature Calibration Bath is a temperature calibration bath and deep-well liquid calibration bath for laboratory and production workflows.

Range
-80 to +180°C
Wide-range liquid calibration
Fluctuation
0.005–0.01°C
Stated over 10 minutes
Uniformity
≤0.01°C
Horizontal and vertical
Working Chamber
Ø130 x 480 mm
18.5 L deep-well bath
LS-CB180 Wide-Range Temperature Calibration Bath

-80°C to +180°C Working Range

One platform covers ultra-low, ambient, and elevated calibration points with heat-transfer fluid selected for each temperature band.

Stable Deep-Well Comparison Zone

The 480 mm chamber depth and stated uniformity support consistent immersion geometry for working and reference probes.

Calibration-System Integration

Probe racks, reference thermometry, fluid management, and traceable calibration documentation can be reviewed as a complete application.

Application & Search Guide

Testing Method

Temperature calibration bath selection and comparison calibration

LS-CB180 Wide-Range Temperature Calibration Bath is selected by matching the calibration range, fluctuation, horizontal and vertical uniformity, working-zone diameter and depth, probe loading, reference thermometer, heat-transfer fluid, and required uncertainty. Published bath stability is only one component of the complete calibration uncertainty budget.

Technical FAQ

How is the correct LS-CB180 configuration selected?

Provide the required temperature points, fluid, vessel or probe geometry, active heat load, ambient conditions, throughput, power supply, and documentation needs. Lithostek then checks the suitable configuration against the complete application.

Does the published temperature limit guarantee loaded performance for LS-CB180?

No. Achievable temperature and pull-down time depend on heat load, fluid, insulation, circulation, ambient temperature, connected volume, and the selected configuration. Cooling or heating capacity should be verified at the actual operating point.

Can LS-CB180 be supplied for different destination-market power requirements?

Electrical supply, plug, protection, installation clearance, communication, calibration documentation, and destination-market compliance are confirmed before quotation and production.