LS-CB80 -80°C Ultra-Low Temperature Calibration Bath

Configured by setpoint, heat load, fluid, and circulation requirements

LS-CB80 -80°C Ultra-Low Temperature Calibration Bath is a temperature calibration bath and deep-well liquid calibration bath for laboratory and production workflows.

Range
-80 to +100°C
Ultra-low calibration range
Fluctuation
0.005–0.01°C
Stated over 10 minutes
Uniformity
≤0.01°C
Horizontal and vertical
Working Chamber
Ø130 x 480 mm
18.5 L deep-well bath
LS-CB80 -80°C Ultra-Low Temperature Calibration Bath

Deep 480 mm Calibration Zone

The cylindrical chamber supports useful immersion depth for comparison work with probes, thermometers, and reference sensors.

Low Fluctuation and Uniformity

Published fluctuation and uniformity values support stable comparison work when the bath is correctly loaded, stirred, and operated with the appropriate fluid.

Application-Based Calibration Review

Lithostek reviews the sensor count, diameter, immersion requirement, reference system, fluid, calibration points, and documentation before quotation.

Application & Search Guide

Testing Method

Temperature calibration bath selection and comparison calibration

LS-CB80 -80°C Ultra-Low Temperature Calibration Bath is selected by matching the calibration range, fluctuation, horizontal and vertical uniformity, working-zone diameter and depth, probe loading, reference thermometer, heat-transfer fluid, and required uncertainty. Published bath stability is only one component of the complete calibration uncertainty budget.

Technical FAQ

How is the correct LS-CB80 configuration selected?

Provide the required temperature points, fluid, vessel or probe geometry, active heat load, ambient conditions, throughput, power supply, and documentation needs. Lithostek then checks the suitable configuration against the complete application.

Does the published temperature limit guarantee loaded performance for LS-CB80?

No. Achievable temperature and pull-down time depend on heat load, fluid, insulation, circulation, ambient temperature, connected volume, and the selected configuration. Cooling or heating capacity should be verified at the actual operating point.

Can LS-CB80 be supplied for different destination-market power requirements?

Electrical supply, plug, protection, installation clearance, communication, calibration documentation, and destination-market compliance are confirmed before quotation and production.