Materials Testing Solutions

LS-HDT3 Three-Station HDT & Vicat Tester

Configured for ISO 75-1, ISO 75-2, ISO 306, ISO 2507, ASTM D648, ASTM D1525 workflows

LS-HDT3 Three-Station HDT & Vicat Tester is a HDT Vicat tester for thermoplastic pipe materials for ISO 75-1, ISO 75-2, ISO 306 workflows.

Stations
3
Independent specimen positions
Temperature
Ambient–300°C
Heating Rate
50 / 120°C/h
Support Span
64 / 100 mm

Three Parallel Test Stations

Three loading positions improve throughput while maintaining independent displacement channels for method comparison and routine production control.

HDT, Vicat and Pipe Workflows

Interchangeable penetrators, edgewise fixtures, spans, and weights allow one bath to support ISO 75, ISO 306, ISO 2507 and related ASTM procedures.

Controlled Standard Heating Rates

Selectable 50°C/h and 120°C/h ramps, bath circulation, and automatic temperature acquisition support repeatable transition-point detection.

Automatic Curve and Result Capture

The controller records temperature and deformation, identifies the configured endpoint, and retains curves and results for reporting.

Application & Search Guide

Testing Method

HDT and Vicat testing for thermoplastic pipe materials

LS-HDT3 Three-Station HDT & Vicat Tester is a multi-station HDT and Vicat tester for plastics, thermoplastic pipes, fittings, and compounds under ISO 75-1, ISO 75-2, ISO 306, ISO 2507, ASTM D648, ASTM D1525. The method, loading nose or penetrator, weight set, support span, heating rate, bath fluid, displacement verification, cooling, and station count are configured together.

Technical FAQ

What is LS-HDT3 Three-Station HDT & Vicat Tester used for?

LS-HDT3 Three-Station HDT & Vicat Tester is used for HDT and Vicat softening temperature testing workflows in civil engineering materials laboratories, quality control labs, research programs, and construction material acceptance testing.

Which standards does LS-HDT3 support?

LS-HDT3 supports ISO 75-1, ISO 75-2, ISO 306, ISO 2507, ASTM D648, ASTM D1525. Lithostek can also configure reporting fields, accessories, and calibration documents around local project or laboratory requirements.

Can Lithostek configure LS-HDT3 for my laboratory?

Yes. Lithostek application engineers can review specimen format, target standards, throughput, power supply, data output, and training requirements before quoting a suitable configuration.

DOCUMENTED QC
CONFIRMED CONFIGURATION
GLOBAL LOGISTICS
TECHNICAL SUPPORT
RETURN TO TOP ↑